3-Stage Clos Example#
Overview#
- A 3-stage Clos and a 5-stage Clos are provided as examples. These designs provide the basic concepts and can be extended if needed.
- For simplicity, both examples are built with 7220-IXR-D series switches which are built on the Trident3 chipset.
- These examples are not exhaustive. There are many different ways to build Clos networks depending on the design goals.
Network Diagram#
Assumptions#
- Uplinks from Leaf to Spine are 100G
- Servers can connect at either 10G or 25G
- Support for single-homed or dual-homed servers (only impact is server density)
- Oversubscription calculations are based on 25G downlink and 100G uplink
- Ratio could change by adding more Spines (up to 8 max)
- Connections out of the fabric will come via a pair of Leaf nodes (Border Leafs)
- Oversubscription ratio is 1:1 between Spine and Border Leaf
Details#
Spine node | 7220-IXR-D3 (32xQSFP28 + 2xSFP+) |
Leaf node | 7220-IXR-D2 (48xSFP28+8xQSFP28) |
Border Leaf node | 7220-IXR-D3 (32xQSFP28 + 2xSFP+) |
# of Spines | 4 |
# of Leafs | 30 |
# of Border Leafs | 2 |
Max single-homed servers | 1,440 (48*30) |
Max dual-homed servers | 720 (48*15) |
Leaf-to-spine oversubscription | 3:1 |